订购/客服:021-61998551/13122364865

干细胞因子(SCF)重组蛋白 (Human,人)

Recombinant Stem Cell Factor (SCF)
别名: KITLG; MGF; SF; KL1; Kitl; FPH2; Kit-Ligand; Steel Factor; Mast Cell Growth Factor; Steel factor; Familial Progressive H
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。 
干细胞因子(SCF)重组蛋白 (Human,人)
货号 规格 可用库存 销售价(RMB) 您的折扣价(RMB) 购买数量
ZY63485HuP-10μg 10μg 现货 1152.00 1152
  • ZY65623HuP

    p53反应基因3(PRG3)重组蛋白(Human,人)
  • ZY65316HuP

    整合素αD(ITGaD)重组蛋白(Human,人)
  • ZY62196EP

    VEGF共调节趋化因子1(VCC1)重组蛋白 (Horse,马)
  • ZY64978HuP

    白细胞免疫球蛋白样受体亚家族B成员2(LILRB2)重组蛋白 (Human,人)
  • ZY64878HuP

    V-Rel网状内皮增生病毒癌基因同源物B(RELB)重组蛋白 (Human,人)
  • ZY66410HuP

    内切核酸酶G(ENDOG)重组蛋白 (Human,人)
  • ZY66053RP

    IgG-Fc片段低亲和力受体Ⅲa(FcgR3A)重组蛋白 (Rat,大鼠)
  • ZY61760PoP

    转化生长因子β2(TGFb2)重组蛋白(Pig,猪)
  • ZY661783Hu2P

    REV1同源物(REV1)重组蛋白 (Human,人2)
  • ZY62132Hu3P

    弗林蛋白酶(FUR)重组蛋白(Human,人3)
  • ZY66534MuP

    含NLR家族Pyrin域蛋白3(NLRP3)重组蛋白(Mouse,小鼠)
  • ZY63048SiP

    红细胞生成素(EPO)重组蛋白(Simian,恒河猴)
熔点:
密度:
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。

干细胞因子(SCF)重组蛋白

规格及价格:

规格 价格
10µg 1152
50µg 2880
200µg 5760
1mg 17280
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Glu26~Ala217
Tags: N-terminal His Tag
Subcellular Location: Membrane, Cytoplasm
Purity: > 95% 
Traits: Freeze-dried powder
Buffer formulation: 20mM Tris, 150mM NaCl, pH8.0, containing 0.01% skl, 5%Trehalose.
Original Concentration: 200µg/mL 
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 5.8
Predicted Molecular Mass: 25.1kDa
Accurate Molecular Mass: 27/29kDa as determined by SDS-PAGE reducing conditions.
[ USAGE ]
Reconstitute in 20mM Tris, 150mM NaCl (pH8.0) to a concentration of 0.1-1.0 mg/mL. Do notvortex
[ STORAGE AND STABILITY ]
Storage:Avoid repeated freeze/thaw cycles.
Store at 2-8ºC for one month.
Aliquot and store at -80ºC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determinedby accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and noobvious degradation and precipitation were observed. The loss rate is less than 5% within theexpiration date under appropriate storage condition.
[ SEQUENCE ]

[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit wasused in clinical diagnostic or any other procedures.
特别提示:本公司的所有产品仅可用于科研实验,严禁用于临床医疗及其他非科研用途!以实际收货产品说明书为准,网站说明书仅供参考。
  • 专业包装 正品保证

  • 快乐服务 售后无忧

  • 会员特权 优惠不断

  • 个人信息 严格保护


© 2005-2026 泽叶生物网站 版权所有,并保留所有权利。
沪ICP备16043273号-2号