订购/客服:021-61998551/13122364865

低氧诱导因子1α(HIF1a)重组蛋白(Human,人2)

Recombinant Hypoxia Inducible Factor 1 Alpha (HIF1a)
别名: HIF1-A; MOP1; PASD8; Basic Helix-Loop-Helix Transcription Factor; ARNT-interacting protein; Basic-helix-loop-helix-PAS p
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。 
低氧诱导因子1α(HIF1a)重组蛋白(Human,人2)
货号 规格 可用库存 销售价(RMB) 您的折扣价(RMB) 购买数量
ZY61986Hu2P-10μg 10μg 现货 864.00 864
  • ZY60020MuP

    纤连蛋白(FN)重组蛋白(Mouse,小鼠)
  • ZY62139HuP

    神经介素B(NMB)重组蛋白(Human,人)
  • ZY60022RP

    抑制素βE(INHbE)重组蛋白(Rat,大鼠)
  • ZY60967RP

    成纤维细胞生长因子18(FGF18)重组蛋白 (Rat,大鼠)
  • ZY64671HuP

    凋亡信号调节激酶I(ASK1)重组蛋白(Human,人)
  • ZY60925Mu3P

    周期素依赖性激酶2(CDK2)重组蛋白 (Mouse,小鼠3)
  • ZY62964RP

    甘氨酸C乙酰转移酶(GCAT)重组蛋白 (Rat,大鼠)
  • ZY60357Hu2P

    S100钙结合蛋白A8(S100A8)重组蛋白 (Human,人2)
  • ZY61040MuP

    Jagged 1蛋白(JAG1)重组蛋白(Mouse,小鼠)
  • ZY64096MuP

    胱天蛋白酶12(CASP12)重组蛋白(Mouse,小鼠)
  • ZY60989HuP

    蛋白激酶Cα(PKCa)重组蛋白 (Human,人)
  • ZY63770HuP

    平滑肌细胞分化特异性抗原(SMTN)重组蛋白(Human,人)
熔点:
密度:
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。

低氧诱导因子1α(HIF1a)重组蛋白

规格及价格:

规格 价格
10µg 864
50µg 2160
200µg 4320
1mg 12960
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Thr218~Thr506
Tags: N-terminal His Tag
Subcellular Location: Nucleus, Cytoplasm
Purity: > 95% 
Traits: Freeze-dried powder
Buffer formulation: 20mM Tris, 150mM NaCl, pH8.0, containing 0.01% SKL, 5% Trehalose.
Original Concentration: 250µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 5.0
Predicted Molecular Mass: 35.9kDa
Accurate Molecular Mass: 40kDa as determined by SDS-PAGE reducing conditions.
[ USAGE ]
Reconstitute in 20mM Tris, 150mM NaCl (pH8.0) to a concentration of 0.1-1.0 mg/mL. Do notvortex
[ STORAGE AND STABILITY ]
Storage:Avoid repeated freeze/thaw cycles.
Store at 2-8ºC for one month.
Aliquot and store at -80ºC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determinedby accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and noobvious degradation and precipitation were observed. The loss rate is less than 5% within theexpiration date under appropriate storage condition.
[ SEQUENCE ]

[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit wasused in clinical diagnostic or any other procedures.
特别提示:本公司的所有产品仅可用于科研实验,严禁用于临床医疗及其他非科研用途!以实际收货产品说明书为准,网站说明书仅供参考。
  • 专业包装 正品保证

  • 快乐服务 售后无忧

  • 会员特权 优惠不断

  • 个人信息 严格保护


© 2005-2024 泽叶生物网站 版权所有,并保留所有权利。
沪ICP备16043273号-2号