订购/客服:021-61998551/13122364865

驱动蛋白家族成员1A(KIF1A)重组蛋白(Human,人)

Recombinant Kinesin Family, Member 1A (KIF1A)
别名: ATSV; UNC104; C2orf20; Axonal Transport Of Synaptic Vesicles; Microtubule-based motor KIF1A; Unc-104- and KIF1A-related
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。 
驱动蛋白家族成员1A(KIF1A)重组蛋白(Human,人)
货号 规格 可用库存 销售价(RMB) 您的折扣价(RMB) 购买数量
ZY60691HuP-10μg 10μg 现货 840.00 840
  • ZY67282MuP

    输入蛋白8(IPO8)重组蛋白(Mouse,小鼠)
  • ZY62479HuP

    组织蛋白酶H(CTSH)重组蛋白 (Human,人)
  • ZY67133HuP

    胸腺生成素(TMPO)重组蛋白(Human,人)
  • ZY63977HuP

    高尔基糖蛋白1(GLG1)重组蛋白 (Human,人)
  • ZY66297HuP

    分离蛋白1(SCRN1)重组蛋白 (Human,人)
  • ZY63061RP

    岩藻糖基转移酶1(FUT1)重组蛋白 (Rat,大鼠)
  • ZY66025RP

    酰基辅酶A氧化酶2(ACOX2)重组蛋白(Rat,大鼠)
  • ZY65466HuP

    磷酸丝氨酸转氨酶1(PSAT1)重组蛋白 (Human,人)
  • ZY62975MuP

    甜菜碱高半胱氨酸甲基转移酶2(BHMT2)重组蛋白(Mouse,小鼠)
  • ZY61095MuP

    Axis抑制蛋白(AXIN)重组蛋白 (Mouse,小鼠)
  • ZY66436RP

    ATP依赖性DNA连接酶Ⅰ(LIG1)重组蛋白 (Rat,大鼠)
  • ZY65114R2P

    视黄醇结合蛋白3(RBP3)重组蛋白 (Rat,大鼠2)
熔点:
密度:
储存条件: 在 2 至 8 °C 下储存一周。在 -20 至 -80 °C 下储存自收到之日起十二个月。

驱动蛋白家族成员1A(KIF1A)重组蛋白

规格及价格:

规格 价格
10µg 840
50µg 2100
200µg 4200
1mg 12600
[ PROPERTIES ]
Source: Prokaryotic expression
Host: E.coli
Residues: Ser21~Leu275
Tags: N-terminal His Tag
Subcellular Location: Cytoplasm
Purity: > 95% 
Traits: Freeze-dried powder
Buffer formulation: 20mM Tris, 150mM NaCl, pH8.0, containing 0.01% SKL, 5% Trehaloseand Proclin300.
Original Concentration: 200µg/mL
Applications: Positive Control; Immunogen; SDS-PAGE; WB.
(May be suitable for use in other assays to be determined by the end user.)
Predicted isoelectric point: 6.0
Predicted Molecular Mass: 32.3kDa
Accurate Molecular Mass: 32kDa as determined by SDS-PAGE reducing conditions.
[ USAGE ]
Reconstitute in 20mM Tris, 150mM NaCl (pH8.0) to a concentration of 0.1-1.0 mg/mL. Do notvortex
[ STORAGE AND STABILITY ]
Storage:Avoid repeated freeze/thaw cycles.
Store at 2-8ºC for one month.
Aliquot and store at -80ºC for 12 months.
Stability Test: The thermal stability is described by the loss rate. The loss rate was determinedby accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and noobvious degradation and precipitation were observed. The loss rate is less than 5% within theexpiration date under appropriate storage condition.
[ SEQUENCE ]

[ IDENTIFICATION ]
[ IMPORTANT NOTE ]
The kit is designed for research use only, we will not be responsible for any issue if the kit wasused in clinical diagnostic or any other procedures.
特别提示:本公司的所有产品仅可用于科研实验,严禁用于临床医疗及其他非科研用途!以实际收货产品说明书为准,网站说明书仅供参考。
  • 专业包装 正品保证

  • 快乐服务 售后无忧

  • 会员特权 优惠不断

  • 个人信息 严格保护


© 2005-2025 泽叶生物网站 版权所有,并保留所有权利。
沪ICP备16043273号-2号